Fabrication of an Electrochemical Sensor Based on a New Nano-ion Imprinted Polymer for Highly Selective and Sensitive Determination of Molybdate

Document Type : Research Paper

Authors

Faculty of Chemistry, Bu-Ali Sina University, Hamedan, Iran

Abstract

In this work a new chemically modified carbon paste electrode was constructed for accurate, simple, sensitive and selective determination of molybdenum (VI) ions. The results of modified electrode by an ion imprinted polymer were compared with those obtained with carbon paste electrode. The results showed the stripping peak currents had a dramatic increase at the modified electrode. Under the optimal conditions, the linear dynamic range and limit of detection were 0.2-500.0 and 0.04 ng mL-1, respectively. The relative standard deviation for five successive measurements of 5.0 and 20.0 ng mL-1 of Mo(VI) ions were 1.8 and 1.4 %, respectively. The reproducibility and stability of the designed modified electrode response were also investigated. By examining the effect of different cations and anions on the determination of the target ion, it was found that the electrode is highly selective for the determination of Mo(VI) ions. Furthermore, the present method was applied to the determination of Mo in real samples with satisfactory results.

Keywords


[1]       T. Madrakian, A. Afkhami, R. Siri, M. Mohammadnejad, Food Chem. 127 (2011) 769.
[2]       P. Deng, J. Fei, J. Zhang, Y. Feng, Food Chem. 124 (2011) 1231.
[3]       J. Di, T. Yang, Talanta 61 (2013) 165.
[4]       J. Di, Y. Tu, Talanta 55 (2001) 783.
[5]       M. Jamaluddin Ahmed, M. Enamil Haque, Anal. Sci. 18 (2002) 433.
[6]       C. Jiang, J. Wang, F. He, Anal. Chim. Acta 439 (2001) 307.
[7]       H.J. Reid, A.A. Bashammakh, P.S. Goodall, M.R. Landon, C. O’Connor, B.L. Sharp, Talanta 75 (2008) 189.
[8]       Y.K. Agrawal, K.R. Sharma, Talanta 67 (2005) 112.
[9]       Y.C. Sun, J.Y. Yang, S.R. Tzeng, Analyst 124 (1999) 421.
[10]    E. Canfranc, A. Abarca, I. Sierra, M.L. Marina, J. Pharm. Biomed. Anal. 25 (2001) 103.
[11]    S.L.C. Ferreira, H.C. dos Santos, R.C. Campos, Talanta 61 (2003) 789.
[12]    J.L. Burguera, M. Burguera, M. Rondón, Talanta 58 (2002) 1167.
[13]    A. Afkhami, A. Bahiraei, T. Madrakian, Mater. Sci. Eng. C 59 (2016) 168.
[14]    A. Afkhami, H. Ghaedi, T. Madrakian, M. Ahmadi, H. Mahmood-Kashani, Biosens. Bioelectron. 44 (2013) 34.
[15]    A. Afkhami, F. Soltani-Felehgari, T. Madrakian, H. Ghaedi, Biosens. Bioelectron. 51 (2014) 379.
[16]    A. Afkhami, H. Ghaedi, T. Madrakian, M. Rezaeivala, Electrochim. Acta 89 (2013) 377.
[17]    A. Afkhami, S. Sayari, F. Soltani-Felehgari, T. Madrakian, J. Iran. Chem. Soc. 12 (2015) 257.
[18]    M. Shamsipur, A. Besharati-Seidani, J. Fasihi, H. Sharghi, Talanta 83 (2010) 674.
[19]    T. Alizadeh, Anal. Chim. Acta 669 (2010) 94.
[20]    Y. Zhai, Y. Liu, X. Chang, S. Chen,  X.  Huang,  Anal. Chim. Acta 593 (2007) 123.
[21]    M. Roushani, Sh. Abbasi, H. Khani, R. Sahraei, Food Chem. 173 (2015) 266.
[22]    W. JoCheong, F. Ali, J. Choi, J. Lee, K. Sung, Talanta 106 (2013) 45.
[23]    M. Zhang, Z. Zhang, Y. Liu, X. Yang, L. Luo, J. Chen, S. Yao, Chem. Eng. J. 178 (2011) 443.
[24]    Y. Ren, P. Liu, J. Feng, J. Ma, Q. Wen, M. Zhang, Chem. Eng. J. 219 (2013) 286.
[25]    V.S. Saji, C.W. Lee, Chem. Sus. Chem. 5 (2012) 1146.
[26]    A. Afkhami, T. Madrakian, M. Soltani-Shahrivar, M.Ahmadi, H Ghaedi, J. Electrochem. Soc. 163 (2016) B68.
[27]    M. Stadlober, K. Kalcher, G. Raber, Anal. Chim. Acta 350 (1997) 319.
[28]    G.V. Prokhorova, V.M. Ivanov, G.A. Kochelaeva, J. Anal. Chem. 55 (2000) 669.
[29]    K. Zarei, M. Alinejad, R. Alizadeh, J. Anal. Chem. 68 (2013) 885.
[30]    P. Deng, J. Fei, J. Zhang, Y. Feng, Food Chem. 124 (2011) 1231.
[31]    K. Tyszczuk, M. Korolczuk, Anal. Chim. Acta 624 (2008) 232.
[32]    Y. Chang Sun, J. Mierzwa, C. Lan, Talanta 52 (2000) 417.
[33]    A.A. Ensafi, T. Khayamian, M. Atabati, Talanta 57 (2002) 785.
[34]    A. Hajian, E. Shams, J. Iran. Chem. Soc. 3 (2006) 32.